1.1 These specifications establish the requirements for test specimens, apparatus, sampling, test procedures and test reports to be used in evaluating the performance of newly installed storefronts, curtain walls and sloped glazing systems and their installation during construction, prior to issuance of the building occupancy permit, but no later than six months after issuance of the occupancy permit. ("Test Area" hereafter referred to as "specimen".) 1.1.1 Specifically excluded from this specification are windows, glass doors and skylights as defined in AAMA AG-07 (if required, these systems shall be tested per AAMA 502).
Also excluded from this specification are commercial entrance systems. Verifying the structural loading resistance performance of storefronts, curtain walls and sloped glazing systems is beyond the scope of this specification. If field testing is required more than six months after the building occupancy permit has been issued, AAMA 511 shall be used.
Additionally, in the event that water penetration testing using the test methods outlined in this specification produces water infiltration that cannot be solely attributed to the glazing system, forensic testing shall be initiated by using AAMA 511 and ASTM E 2128. The determination of the source(s) of water penetration from a wall or roof component other than the glazing system requires forensic investigation and testing outside the scope of this specification.
1.2 The purpose of this specification is to provide a method which can be used to evaluate the installed performance of storefronts, curtain walls and sloped glazing systems for resistance to water penetration under controllable and reproducible test conditions intended to simulate wind driven rain events. This specification may also be used to evaluate the installed air leakage of"punched opening" curtain walls, storefronts and sloped glazing. Field air leakage testing is not recommended for a portion of continuous systems due to the complexity of compartmentalizing air chambers and cavities within these systems.
1.3 The primary units of measure in this document are metric. The values stated in SI units are to be regarded as the standard. The values given in parentheses are for reference only.
检测项目及标准
序号 | 检测标准 | 检测对象 | 检测项目 |
---|---|---|---|
1 | 《新安装的面板,幕墙及斜玻璃窗系统现场检测规范》 AAMA503-14 2.1.1 | 门面,外墙和倾斜玻璃装置系统 | 现场气密性能 |
2 | 《新安装的门面,幕墙及斜玻璃窗系统现场检测规范》 AAMA503-14 2.1.2 | 门面,外墙和倾斜玻璃装置系统 | 现场水密 |
3 | 《动压下门面,外墙和倾斜玻璃装置系统的现场检验》 AAMA501.2-15 | 门面,外墙和倾斜玻璃装置系统 | 现场水密 |
4 | 新安装的门面,幕墙及斜玻璃窗系统现场检测规范 | 门面,外墙和倾斜玻璃装置系统 | 现场水密 |
5 | 新安装的面板,幕墙及斜玻璃窗系统现场检测规范 | 门面,外墙和倾斜玻璃装置系统 | 现场气密性能 |
6 | 动压下门面,外墙和倾斜玻璃装置系统的现场检验 | 门面,外墙和倾斜玻璃装置系统 | 现场水密 |
温馨提示:以上内容仅供参考,更多检测相关信息请咨询官方客服。